You are here

Remarks
1/f Yuragi

By this sophosticated formula, 1/f Yuragi, in varying air velocity and controlling wind force, the new ceiling fan presents you a peaceful and comfortable breeze. Incorporated with the human-concerned technology, this kind of rththm also maintains your external body temperature and keep you in a better and relaxing physical condition

Remarks
3D Circulation Airflow

3D circulation airflow is divided into two modes, including Front Airflow and Upwards Airflow. Usually, various types of dirts appear at different position between the ceiling and the floor in the room, and they can be purified by different modes of 3D airflow respectively. Front Airflow mode cleans up house dust spreading within 30cm above the floor, while Upwards airflow removes odor floating in the air.

Remarks
Advanced blade design

To optimize airflow performance of the ventilating fan, the new blade design applies advanced aerodynamic principle that minimizes any obstacle against the airflow. Air volume is maintained while rotation speed can be reduced, resulting lower noise level and power consumption.

Remarks
Cut-off safety switch

Cut-off safety switch is equipped to cut off power supply while dangerous wear and tear of the shaft or bolt are detected.

Remarks
Double chamber

Distinctive structure of "Double Chamber" minimizes the transmission of noise from fan and motor to exterior. This technology further reduces the operation noise to incredibly low level below 30dB(A) by "Resonance-Noise-Absorption" operation, which creates a tranquility and silent environment

Remarks
nanoe

nanoe Ion is long-life micro particles created from water, it can penetrate into fabrics thoroughly and reach in far corners to absorb the allergens. As the ions are wrapped in water molecules that the effect is long-lasting. Furthermore, the nanoe ions condense as moisture in the air that water replenishment for the product is not required.

Remarks
Safety wire

Safety wire is adopted to secure the fan motor with the ceiling hook that prevents falling of the motor when detaching of the fan moto from the pipe rod occurs.

Remarks
Wobbling reduction mechanism

Wobbling reduction mechanism can reduce wobbing between bolt, motor shaft and pipe. it can minimize wearing of the parts to prevent falling of fan.

24CHG

  • Super low noise design
  • Long life ball bearing motor
  • Taper blade sirocco fan
  • Rasonance-Noise-Absorption Structure
  • Reverse flow prevention shutter
  • Pre-installed power cord

24CHG

  • Super low noise design
  • Long life ball bearing motor
  • Taper blade sirocco fan
  • Rasonance-Noise-Absorption Structure
  • Reverse flow prevention shutter
  • Pre-installed power cord
  • Exhaust type
  • The fan shall be suitable for ceiling mounting
  • HP (Half-pitch) motor with thermal cut-off
  • Well lubricated bearing for long life operation
  • Pre-installed power cord
  • Unique design of double orifice minimizes noise transmission from fan
  • High performance taper blade designed Sirocco Fan adopted to control air turbulence effectively
  • Installation size = 240 x 240 mm
Voltage [V]
220 230 240
Frequency [Hz]
50 60
24CHG Dimension
24CHG Dimension
24CHG Dimension
24CHG Dimension
Air Volume [CMH] 200
Consumption Normal [W] 18
Noise - Hi [dB(A)] 33.50
RPM Normal [min-1] 760
Weight [kg] 2.80
Air Volume [CMH] 190
Consumption Normal [W] 22
Noise - Hi [dB(A)] 33.50
RPM Normal [min-1] 730
Weight [kg] 2.80
Voltage [V]: 
220
Frequency [Hz]: 
60
Air Volume

[CFM]

112

[CMH]

190
Consumption [W]

Normal

22
Noise [dB(A)]
Noise - Hi [dB(A)]: 
33.50
RPM [min-1]
730
Duct Size [mm]
Duct Size [mm]: 
Ø100
Installation Space [mm]
Installation Space [mm]: 
240 x 240
Weight [kg]
Weight [kg]: 
2.80
Air Volume
Inches of H2O CFM
0 109
0.1 99
0.125 96
0.25 75
0.375 47
Required statement for:
Performance certified is installation type A: Free inlet, Free outlet. Speed(RPM) shown is based on actual speed of test.
Noise[dB(A)]
Inches of H2O Sones
0 1.0
0.1 1.2
0.125 1.2
0.25 1.5
0.375 2.4
Required statement for sound (SONE):
The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA International Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels.
AMCA RPM

860
AMCA Watt

23.60
HideWatt For IEC
22
HideWeight [kg]
2.80
Air Volume [CMH] 210
Consumption Normal [W] 20
Noise - Hi [dB(A)] 35
RPM Normal [min-1] 800
Weight [kg] 2.80
Air Volume [CMH] 210
Consumption Normal [W] 22
Noise - Hi [dB(A)] 36
RPM Normal [min-1] 850
Weight [kg] 2.80
Voltage [V]: 
240
Frequency [Hz]: 
50
Air Volume

[CFM]

124

[CMH]

210
Consumption [W]

Normal

22
Noise [dB(A)]
Noise - Hi [dB(A)]: 
36
RPM [min-1]
850
Duct Size [mm]
Duct Size [mm]: 
Ø100
Installation Space [mm]
Installation Space [mm]: 
240 x 240
Weight [kg]
Weight [kg]: 
2.80
Air Volume
Inches of H2O CFM
0 116
0.1 100
0.125 94
0.25 72
0.375 33
Required statement for:
Performance certified is installation type A: Free inlet, Free outlet. Speed(RPM) shown is based on actual speed of test.
Noise[dB(A)]
Inches of H2O Sones
0 1.2
0.1 1.3
0.125 1.4
0.25 1.6
0.375 2.1
Required statement for sound (SONE):
The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated per AMCA International Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels.
AMCA RPM

890
AMCA Watt

23.50
HideWatt For IEC
22
HideWeight [kg]
2.80
Voltage [V]
220 230 240
Frequency [Hz]
50 60
Model
General

24CHG_curve_v220_f50_General

Curve Data: 
[{"subtitle":"24CHG_220_50","title":"24CHG_220_50","xmax":250,"xmin":0,"ymax":150,"ymin":0},[[0,104.65],[11.9,103.45],[23.21,101.46],[33.93,99.47],[44.05,96.68],[54.76,93.5],[66.07,89.92],[75.6,86.34],[85.12,81.96],[94.64,77.59],[102.98,73.21],[111.9,68.04],[120.24,63.26],[129.17,57.29],[137.5,51.72],[146.43,45.76],[155.36,38.59],[162.5,33.02],[170.24,27.06],[179.17,19.5],[186.31,13.13],[192.86,7.16],[200,0]]]

24CHG_curve_v220_f60_General

Curve Data: 
[{"subtitle":"24CHG_220_60","title":"24CHG_220_60","xmax":250,"xmin":0,"ymax":150,"ymin":0},[[0,134.49],[12.5,132.89],[24.4,129.71],[35.71,126.53],[47.02,121.75],[57.14,117.37],[67.26,112.2],[75.6,107.43],[85.12,101.46],[94.05,95.89],[101.79,90.32],[108.93,84.75],[116.07,78.38],[124.4,71.62],[132.74,64.85],[141.07,56.9],[149.4,47.75],[157.14,38.99],[163.1,31.83],[169.05,25.46],[174.4,19.1],[180.36,11.54],[185.12,5.57],[188.69,0.4]]]

24CHG_curve_v230_f50_General

Curve Data: 
[{"subtitle":"24CHG_230_50","title":"24CHG_230_50","xmax":250,"xmin":0,"ymax":150,"ymin":0},[[0,105.25],[11.9,103.85],[25,101.86],[39.88,99.47],[51.79,96.29],[64.29,93.1],[76.79,88.73],[87.5,84.75],[98.81,79.58],[108.33,74.8],[119.05,69.23],[128.57,63.66],[136.9,58.49],[145.24,52.52],[153.57,46.95],[160.71,40.98],[168.45,35.01],[175.6,29.05],[184.52,22.28],[191.67,15.92],[198.21,10.74],[204.17,5.17],[208.93,0.4]]]

24CHG_curve_v240_f50_General

Curve Data: 
[{"subtitle":"24CHG_240_50","title":"24CHG_240_50","xmax":250,"xmin":0,"ymax":150,"ymin":0},[[0,114.7],[12.5,111.9],[25,109.52],[36.9,105.95],[48.21,102.38],[58.93,98.81],[69.05,94.84],[78.57,90.48],[88.69,85.71],[97.02,81.35],[107.74,75.79],[116.07,71.03],[126.19,65.48],[135.71,59.52],[143.45,54.76],[151.19,48.81],[157.74,44.05],[165.48,37.7],[173.21,31.75],[180.36,26.19],[187.5,19.84],[194.64,13.89],[201.19,8.33],[209.52,0.4]]]
VGX100K
  • Vent cap (with net)
  • Round type
  • High strength material
  • Excellent anti-rust capability
  • Duct diameter = Ø100mm
VCX100K
  • Vent cap
  • Round type
  • High strength material
  • Excellent anti-rust capability
  • Duct diameter = Ø100mm
MGX100K
  • Pipe hood (with net)
  • Round type
  • High strength material
  • Excellent anti-rust capability
  • Duct diameter = Ø100mm
MCX100K
  • Pipe hood
  • Round type
  • High strength material
  • Excellent anti-rust capability
  • Duct diameter = Ø100mm